Logic Import Dialog Box showing CIMPLICITY Connectivity.

 

Description

GE Fanuc Automation Corporation's CIMPLICITY product is an integrated management and control system used to monitor and control factory floor equipment such as programmable logic controllers (PLCs), CNCs, robots and other manufacturing devices.

Direct program upload and download is possible from the LADDERS interface with a run-time link to the CIMPLICITY application software. The screen pictures below show the user selecting NETWORK as his UPLOAD source. This causes LADDERS to connect to CIMPLICITY and create a POPUP MENU of the DEVICES from the CIMPLICITY Device Communications Open Architecture Interface (DEVCOM API).

 

Features

 
bulletUpdate LADDERS documentation files directly from floor devices

bulletDirectly compare floor device logic to Production Library

bulletConvert between DOS and Host file formats

bulletLADDERS Batch Compare Reports (LBCR) - unattended compares from a DCL command

bulletLADDERS Automated Compare Reports (LACR) - user scheduled up to 3 times daily, activated by actual logic changes

bulletLearn and use just one User Interface

bulletIntegration example...

 



The alert "CONNECTING to GE Fanuc's CIMPLICITY" appears momentarily and then the user can pick his DEVICE NAME as shown here...


The CIMPLICITY Device Configuration can be viewed from LADDERS after a device is selected as shown in the picture below.



 

bulletFile format conversions

LADDERS can convert GE Fanuc Logicmaster PC files into CIMPLICITY VAX files and vice versa. This ability provides a method of backing up program files from the VAX on IBM PC floppies for use with the WorkMaster if the network is unavailable in an emergency. The pictures below show this conversion.

Logicmaster to CIMPLICITY conversion (GE Series Six)


This configuration may be changed by the LADDERS user.

LADDERS CIMPLICITY Domain Configuration Screen

bulletOther conversions

The EXPORT TO parameter offers the user several choices of FILE TYPES as shown below. This simple interface allows the user to convert a job to any file format supported by LADDERS by simply selecting the new format during a compile.

 

 

Hardware Requirements

bulletAny VAX, MicroVAX, VAXstation, AlphaWorkstation or AlphaServer.

Supported Terminal. (See LADDERS Shared Image 'Features'.)

Supported Printer.  (See LADDERS Shared Image 'Features'.)

 

 

Software Requirements

bulletDigital Equipment Corporation OpenVMS Operating System.

OpenVMS Version 4.7 - 7.1 supported.

 

bulletCIMPLICITY D/V for VMS, Version 4.0 or higher

GE Fanuc CIMPLICITY

 

CIMPLICITY is a registered trademark of GE Fanuc Automation Corporation

 

 
Email webmaster@mcode.com with questions or comments about this web site.
Copyright © 1990-2006 MicroCODE Incorporated.   All rights reserved.